CFRGD - LEAD-ACID BATTERY,ELECTRIC STORAGE BATTERY
- MSDS: CFRGD
- Manufacturer: EXIDE CORP GENERAL BATTERY CORP
- Product Name: LEAD-ACID BATTERY,ELECTRIC STORAGE BATTERY
- National Stock Number: 6140-01-203-8983
Product Identification
Product ID:LEAD-ACID BATTERY,ELECTRIC STORAGE BATTERY
MSDS Date:02/01/1996
FSC:6140
NIIN:01-203-8983
MSDS Number: CFRGD
Responsible Party
READING, PA 19601
US
Emergency Phone: 610-378-0500/800-424-9300(CHEMTREC)
Info Phone: 610-378-0500
Cage: 08163
Contractor
Telephone: 215-378-0527/800-424-9300(CHEMTREC)
Cage: 08163
Ingredients
LEAD (SARA 313) (CERCLA) (INORGANIC CMPDS OF)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 53%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.05MG/M3, A3; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ANTIMONY (SARA 313) (CERCLA) (INORGANIC CMPDS OF )
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: 0.2%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG (SB)/M3; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ARSENIC (SARA 313) (CERCLA) (INORGANIC CMPDS OF)
CAS: 7440-38-2
RTECS: CG0525000
Fraction By Weight: 0.003%
OSHA PEL SEE 1910.1018
ACGIH TLV: 0.01 MG/M3, A1; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
TIN (INORGANIC CMPDS OF )
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: 0.06%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9596
SULFURIC ACID (SARA 302/313) (CERCLA) (ELECTROLYTE,
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: 30-40%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3/3 STEL; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
POLYPROPYLENE (CASE MATERIAL)
CAS: 9003-07-0
RTECS: TR5000000
Fraction By Weight: 5-6%
HARD RUBBER (CASE MATERIAL)
SILICON DIOXIDE (GEL CELL BATT ONLY)
CAS: 60676-86-0
RTECS: VV7328000
Fraction By Weight: 3-5%
OSHA PEL SEE TABLE Z-3
ACGIH TLV: 0.1 MG/M3 RDUST;9596
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACID:HARMFUL BY ALL ENTRY ROUTES.PB
CMPDS:HAZ EXPO CAN OCCUR ONLY WHEN PROD HEATED >MELT
PT,OXIDIZE,OTHERWISE PROCESSED/DMG TO CREATE
DUST/VAP/FUME.INHAL:ACID-SEVERE RESP IRRIT.PB-IRRIT OF UPPER RESP
TRACT,LUNGS.INGEST:ACID-SEVERE IRRIT
OFMOUTH/THROAT/ESOPAHGUS/STOMACH.PB-ABD PAIN,NAU,VOMIT,DIARR,SEVERE
CRAMP(SIGN/SY)
Explanation of Carcinogenicity:PER MSDS:PB CMPDS-2B
CARC;ARSENIC-NTP/IARC/OSHA;ACID-STRONG INORG ACID MIST W/SULFURIC
ACID-NOT APPLY TO BATT ELECTROLYT
Effects of Overexposure:HEALTH:LEAD RAPIDLY TO SYSTEMIC
TOXICITY.SKIN:ACID-SEVERE IRRIT,BURNS,ULCERATION.PB-NOT ABSORG THRU
SKIN.EYE:ACID-SEVERE IRRIT,BURN,CORNEA
DMG,BLINDNESS.PB-IRRIT.OVEREXPO:SEVERE SKIN IRRIT,CORNEA DMG,
BLINDNESS,UPPER RESP IRIRT,HEAD,FTG,ABDPAIN,LOSS OF
APPETITE,MUSCULAR ACHES,WEAK,SLEEP DISTURB,IRRITABILIYT.
Medical Cond Aggravated by Exposure:CHRON OVEXPO:TOOTH ENAMEL
EROSION,INFLAMM NOSE/THROAT/BRONCH TUBES,ANEMIA,NEUROPATHY(MOTOR
NERV,WRIST DROP),KID DMG,M/FE REPROD CHANGES. AGGRAV:LUNG DMG,PULM
CONDITIONS,SKIN/KID/LIV/NEURO DISEASES,EYE
First Aid
First Aid:INHAL:ACID-REMOVE TO FRESH AIR IMMED.BREATH DIFFI GIVE
OXY.PB-REMOVE FROM EXPO.GARGLE,WASH NOSE/LIPS.CONSULT
DR.INGEST:ACID-GIVE LG QUANT OF H2O.DONT INDUCE VOMIT.CONSULT
DR.PB-CONSULT DR IMMED.SKIN:A CID-FLUSH W/LG AMTS OF H2O @LEAST
15MINS.REMOVE CONT CLOTH/SHOES.PB-WASH IMEMD
W/SOAP/H2O.EYE:ACID/PB-FLUSH IMMED W/LG AMTS OF H2O @LEAST
15MINS.CONSULT DR IMMED.
Fire Fighting
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:4.1 HYDROGEN
Upper Limits:74.2
Extinguishing Media:CO2, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE +PRESS SCBA.BEWARE OF ACID SPLATTER DURING
H2O APPLICATION,WEAR ACID-RESIST CLOTH/GLVOE/FC/EYE PROT.BATT ON
CHARGE SHUT OFF POWER TO CHARGING EQPMT(SUPPLE)
Unusual Fire/Explosion Hazard:IN OPERATION BATT GENERATE/RELEASE FLAMM
HYDROGEN GAS.MUST ALWAY S BE ASSUMED TO CONTAIN GAS0IF IGN BY
BURNING CIGARETTS,NAKE FLAME,SPARK CAUSE BATT EXPLO(SUPP)
Accidental Release
Spill Release Procedures:STOP FLOW,CONTAIN/ABSORB SM SPILL W/DRY
SAND,EARTH,VERMI-NO COMBUST MATL. NEUTRA ELECTROLYTE W/SODA
ASH,NAHCO3,LIME,ETC.WEAR ACID RESIST CLOTH/ETC.DONT ALLOW UNNEUTRA
ACID TO SEWER.NEUTRA ACID MANAGED IAW APPROV LOC/STATE/FED
REQMT.CONSULTAGENCY,ETC
Neutralizing Agent:SODA ASH, SODIUM BICARBONATE (NAHCO2), LIME, ETC.
Handling
Handling and Storage Precautions:STORE UNDER ROOF IN COOL DRY WELL
VENTI AREA SEPARATED FRM INCOMPAT MATLS/ACTIVITIES CREATE
HEAT/FLAME/SPARK,ON SMOOTH IMPERV SURF PROT FRM ACID SPILL
Other Precautions:KEEP AWAY FRM METALLIC OBJ-BRIDGE TERMINALS,CREATE
DANGEROUS SHORT CIRCUIT.HNDLG CAREFUYLLY,AVOID TIPPING.INCR RISK OF
ELECT SHOCK FRM STRING OF CONNECTED BATT EXCEED 3-12V UNITS. PB
INCOMPAT:KNO3,PER MANGANATE,PEROXIDES,NASCENT H2,RED AGENT
Exposure Controls
Respiratory Protection:NONE REQURIE DUNDER NORMAL CONDITIONS.WHEN CONC
OF SULFURIC ACID MIST ARE KNOWN TO EXCEED PEL USE NIOSH OR MSHA
APPROV RESP PROTECTION.
Ventilation:STORE/HNDL IN WELL-VENTILATED AREA.IF MECHANICAL
VENTILATION IS USED COMPONENTS MUST BE ACID-RESISTANT.
Protective Gloves:RUBB,PLAST ACID-RESIST W/ELBOW-LEN GAUNT
Eye Protection:CHEM GOGGLES OR FACE SHIELDS
Other Protective Equipment:ACID-RESIST APRON.SEVERE EXPO/EMERG
CONDITIONS-ACID-RESIST CLOTH/GLV/BOOTS.EMERG EYEWASH
STATIONS,SHOWERS W/UNLIMITE H2O
Work Hygienic Practices:CHARGING SPACE SHOULD BE VENTED.KEEP VENT CAPS
IN POSITION.PROHIBIT SMOKE/FLAME-SPARK CREATION NEARBY.WEAR PPE
WHEN CHAR
Supplemental Safety and Health
PHYS DATA ON ELECTROLYTE. FIREFIGHT:NOTE THAT STRINGS OF SERIES
CONNECTED BATT MAY STILL POSE ELECT SHOCK RISK EVEN WHEN CHARGING
EQPMT SHUT DOWN. FIRE/EXPLO:W/CASING FRAG/CORR LIQ ELECTROLYTE
DISPERS .CAREFULLY FOLLOW MFG INSTRUCTIONS FOR INSTALL/SERV.KEEP
AWAY ALL IGN SOURCES/DONT ALLOW METALLIC ART TO CONTACT TERMINA
Chemical Properties
HCC:C1
Boiling Pt:B.P. Text:203F,95C
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:17-11
Vapor Density:>1
Spec Gravity:1.230-1.350
pH:NP
Viscosity:NP
Evaporation Rate & Reference:<1, BUTYL ACETATE=1
Solubility in Water:100% COMPLETE
Appearance and Odor:CLEAR LIQ W/SHARP PENETRATING PUNGENT ODOR.BATT MFG
ARTICLE,NO APPARENT ODOR.
Percent Volatiles by Volume:NA
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
ACID:COMBUST/ORG MATLS,STRONG RED AGENTS,METALS,STRONG
OXID,H2O,SO3.PB:STRONG ACIDS,BASES,HALIDES,HALOGENS,(OTHER PRECA)
Stability Condition to Avoid:PROLONGED OVERCHARGE AT HIGH
CURRENT;SOURCES OF IGNITION.
Hazardous Decomposition Products:ACID:SO3,CO,H2SO4 MIST,SO2.PB:TEMP
>MELT PT-TOXIC METAL FUME/VAP/DUST;ACID/BSE/H2 CONTACT GIVES
HIGHTLY TOXIC ARSINE GAS
Disposal
Waste Disposal Methods:SPENT BATT:SEND TO 2ND PB
SMELTER(RECYC).ACID:NEUTRA SLURRY INTO SEAL ACID RESIST CNTNR,DISPO
AS HAZ WASTE AS APPLICABLE.LG H2O DIL SPILL AFT NEUTRA/TEST,MANAGE
IAW APPROV LOC/STATE/FED REQMTS.CONSULT STATE ENVIRO AGENCY &/OR
FED EPA.EPA#:D002.CERCLA
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.